Item/ModelPWX1500LPWX1500MLPWX1500MHPWX1500H
External control *1Output voltagecontrol (VPGM)0 % to 100 % of the rated output voltage
Selectable control voltage range: 0 V to 5 V or 0 V to 10 V
Accuracy5 % of rtg
Output current control (IPGM)Selectable control voltage range: 0 V to 5 V or 0 V to 10 V
0 % to 100 % of the rated output voltage Selectable control voltage range: 0 V to 5 V or 0 V to 10 V
Accuracy5 % of rtg
Output on/off control [OUTPUT ON/OFF CONT]Possible logic selections:Turn the output on using a LOW (0 V to 0.5 V) or short-circuit, turn the output off using a HIGH (4.5 V to 5 V) or open-circuit. Turn the output on using a HIGH (4.5 V to 5 V) or open-circuit, turn the output off using a LOW (0 V to 0.5 V) or short-circuit.
Output shutdown control [SHUT DOWN]Turns the output off with a LOW (0 V to 0.5 V) or short-circuit.
Alarm clear control [ALM CLR]Clears alarms with a LOW (0 V to 0.5 V) or short-circuit.

*1. J1 connector on the rear panel