Electronic Load
ELECTRONIC LOAD
Various operations not possible with variable resistors are possible.
When measuring the characteristics of a device that outputs energy, such as a power supply or battery, a load that consumes energy is required. Variable resistors can be used for simple loads, but they may not be suitable for loads with complex behaviors. Electronic load devices are devices that use semiconductors such as transistors instead of variable resistors. Electronic load devices using semiconductors can be used as a variety of loads by incorporating a control circuit, since the current and voltage can be varied freely.

DC Electronic Load
- 3U Size
- Rated power of 20 kW
- Regenerative efficiency of over 90%
High-Capacity RegenerativeElectronic Load
- Maximum operating voltage of 1500 V
- Operating modes: CC, CR, CV, CP
- Up to 25 units (500 kW) can be operated in parallel
- Equipped with a touch panel display
- Pre-charge function
- I-V characteristic function
- LAN, USB, RS232C, external analog control (isolated type) as standard
- Arbitrary I-V characteristics: Installed “ARB mode”
- Models with impedance measurement function
Multifunctional Electronic Load (CC/CV/CR/CP)
- 200W, 400W, 1200W, 3 models
- Operation voltage: 0.25V to 150V (from 0.05V)
- High speed slew rate: 60A/µs
- Arbitrary I-V characteristics: Installed “ARB mode”
- Parallel operation feature: The total current and power capacities can be increased to the maximum of 10.8kW (2160A) by connecting the booster units.
- New high visibility color display.
- PLZ-5WZ Series Models with Impedance Measurement Function
- Ultra Compact
- Parallel operation: Max. 100kW/ 2000A
Multifunctional Electronic Load (CC/CV/CR/CP)
- Operating voltage: 10V to 1000V (Min. 1.5V)
- Power capacity: 1kW / 2kW / 4kW / 12kW / 20kW(5 models)
- 100 kW/ 2000 A with parallel operation (Max. 5 units), connectable with different models.
- LAN (LXI Compliant) / USB / RS232C standard interface *GPIB optional
- Synchronized operation / Sequence function
- Arbitrary I-V characteristics: Installed “ARB mode”
- Parallel operation of load units
- Input operating voltage 0V model
Multifunctional Electronic Load (CC/CV/CR/CC+CV/CR+CV)
- High-speed response supporting a maximum slew rate of 2.4 A/µs (PLZ150U)
- 0-V input operating voltage model (PLZ70UA)
- Up to 5 load units of the same model can be operated in parallel.
- Timer function and time/voltage measurement functions enable evaluation of battery discharge characteristics
- Equipped with sequence and switching functions
- GPIB/RS232C are standard interface