PFX2500_Comparison of PFX2500 series specifications

ItemPFX2512PFX2532
Rating60 V / 50 A60 V / 200 A
Communication interfaceLANLAN
Monitoring data minimum time interval0.1 s0.1 s
High speed data sampling*4✔︎ (Selected form 1 ms/10 ms/ 100 ms maximum 6000 points for every profile)
Charge/discharge mode9 modes
Charging: CC, CC-CV(Cell CV Voltage)*1
Discharging: CC, CP,CC-CV(Cell CV Voltage)*1, CP-CV(Cell CV Voltage)*1
Others: Pattern(CC, CP, Cell CV voltage*2), I-V, Pause
Test condition configurationIndividual Profile Setting (unlimited) for Charging/Discharging, etc
Conditional branching function from charge/discharge results is available.
Seamless charge/discharge✔︎ (Response within 50 ms (TYP)*3)
Rest time controlThe time variable by cell temperature

*1 Can be set only when the optional OP02-PFX Volt/Thermometer Unit or OP03-PFX Voltmeter Unit is installed. *2 Can be set only when the optional OP02-PFX Volt/Thermometer Unit or OP03-PFX Voltmeter Unit is installed. Step time can be used in more than 500 ms. *3 It is defined as the time for the charge/discharge current to change from 10 % to 90 % of the preset value (ratedvalue). *4 The main body voltmeter/ammeter is applicable. (Cell voltmeters are not supported.)