| Operation mode | Harmonic mode / Flicker mode |
|---|
| Control type | Resistive load method (forced air cooling) |
|---|
| Input voltage range | Single-phase 100 VAC to 240 VAC |
|---|
| Input voltage type | Single-phase two-wires, Single-phase three-wires (change by per phase), Three-phase four-wires (change by per phase) |
|---|
| Input current | 2.3 A ±5 % (when at the setting voltage of 230 V), 1.0 A ±5 % (when at the setting voltage of 100 V) *Maximum power when through the phase contorl |
|---|
| Allowable current for the external load connecting terminal | Approx. maximum 10 A |
|---|
| Harmonic generation method | Phase control |
|---|
| Phase angle variation range | Approx. 10 to 170 (when at the setting voltage of 100 V or 230 V) |
|---|
| Thermal protection | Yes (ALARM lights on, a buzzer sounds) |
|---|
| Flicker generation method | Square-wave ON/OFF control by the electronic timer |
|---|
| Flicker frequency setting range | Approx. 0.5 Hz to 20 Hz |
|---|
| Warm-up time | Approx. 10 minutes |
|---|
| Power supply for the activation | Single-phase 86 VAC to 264 VAC, less than 75 W (possible for common use of the measurement circuit) |
|---|
| Withstanding voltage | Between the Input and FG(Frame Ground) 1830 V, less than 5 mA |
|---|
| Dimensions | 214(W)×124(H)×400(D)mm (Excluding the projected components) |
|---|
| Weight | Approx. 6 kg |
|---|